| Items |
TSBSB05 TSBSB Shock Relay for Overload Protection |
TSBSB10 TSBSB Shock Relay for Overload Protection |
TSBSB30 TSBSB Shock Relay for Overload Protection |
TSBSB60 TSBSB Shock Relay for Overload Protection |
TSBSB100 TSBSB Shock Relay for Overload Protection |
|||||
| Transformer | N/A | N/A | N/A | N/A | N/A TSB2CT100 | |||||
| Motor | N/A | |||||||||
| Motor HP 230 VAC | N/A 1/8 to 1 hp | N/A 2 to 3 hp | N/A 5 to 7 hp | N/A 10 to 15 hp | N/A 20 to 25 hp | |||||
| Motor HP 460 VAC | N/A 1/4 to 3 hp | N/A 3 to 5 hp | N/A 7 to 15 hp | N/A 20 to 30 hp | N/A 40 to 60 hp | |||||
| Operation Power | N/A 24 to 240 V AC/DC +/- 10%, 50/60 Hz | |||||||||
| Maximum Motor Voltage | N/A 600 VAC at 50/60 Hz | |||||||||
| Load Current Setting Range | N/A 0.5 to 6 A | N/A 1 to 12 A | N/A 3 to 30 A | N/A 5 to 60 A | N/A 10 to 100 A | |||||
| Trip Output Relay Status - Energized/Fail Safe to Open | N/A Manual Setting | |||||||||
| Trip Output Relay Status - Energized/Fail Safe Close | N/A Automatic Setting | |||||||||
| Trip Output Relay Contact Rating | N/A 3A Load | |||||||||
| Start Time Setting Range | N/A 0.2 to 10 s | |||||||||
| Shock Time Setting Range | N/A 0.2 to 5 s | |||||||||
| Input Voltage for Operation | N/A | |||||||||
| Allow. Input Voltage Fluctuation | N/A 10 % | |||||||||
| Meter Fine Tuning Adjustment | N/A | |||||||||
| Output Contact1 | N/A 3A/250 VAC, Resistive | |||||||||
| Test Button | N/A Yes | |||||||||
| Test Function | N/A Built In | |||||||||
| Withstanding Voltage | N/A 2000 VAC, 5 mA at 60 Hz for 1 min. between terminal and enclosure | |||||||||
| Surface Color | N/A | |||||||||
| Weight_SYN | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 1.540 lb0.70 kg | |||||
| Shock Relay Power Supply | N/A 90 to 240 VAC | |||||||||
| Power Consumption | N/A 2 W | |||||||||
| Operating Temperature Range | N/A -4 to 140 ºF-20 to 60 ºC | |||||||||
| Max. Elevation | N/A 2000 m6500 ft | |||||||||
| Operating Humidity | N/A 45 to 85% R.H. with no condensation | |||||||||
| Atmosphere | N/A Free of corrosive gas and dust. Pollution degree 3 or below when installed in control box | |||||||||
| Protection Rating | N/A IP20 | |||||||||
| Construction Material | N/A Material Lower Housing - PA66 Material Upper Housing - PA6 Terminal Cover - PA6 | |||||||||
| Industry Standards/Certifications_SYN | N/A CCC - China CE Marking - Europe RoHS Compliant UL/cUL - North America | |||||||||
| Mounting Type_SYN | N/A 35 mm DIN Rail or Mounting Plate | |||||||||
| Ambient Temperature Range_SYN | N/A -22 to 158 ºF-30 to 70 ºC | |||||||||
|
||||||||||