TSBSB Shock Relay for Overload Protection
Electronic - Shock Relays
- TSBSB Shock Relay series – Overload protection has built-in reset button, test button, fail-safe contacts with manual and automatic reset feature
TSBSB Shock Relay senses the problem before downtime, maintenance and equipment damage occur, saving you time and money. Install it on a line, set the overload parameters, and Shock Relay takes care of the rest. If an overload is detected, the Shock Relay can send a warning or shut down the line – quick and reliably. Correct the problem and you’re up and running again in minutes.
Unit of Measure
Items |
/Asset/TSBSB.jpg TSBSB05 TSBSB Shock Relay for Overload Protection |
/Asset/TSBSB.jpg TSBSB10 TSBSB Shock Relay for Overload Protection |
/Asset/TSBSB.jpg TSBSB30 TSBSB Shock Relay for Overload Protection |
/Asset/TSBSB.jpg TSBSB60 TSBSB Shock Relay for Overload Protection |
/Asset/shock_relay2.jpg TSBSB100 TSBSB Shock Relay for Overload Protection |
|||||
Transformer | N/A | N/A | N/A | N/A | N/A TSB2CT100 | |||||
Motor | N/A | |||||||||
Motor HP 230 VAC | N/A 1/8 to 1 hp | N/A 2 to 3 hp | N/A 5 to 7 hp | N/A 10 to 15 hp | N/A 20 to 25 hp | |||||
Motor HP 460 VAC | N/A 1/4 to 3 hp | N/A 3 to 5 hp | N/A 7 to 15 hp | N/A 20 to 30 hp | N/A 40 to 60 hp | |||||
Operation Power | N/A 24 to 240 V AC/DC +/- 10%, 50/60 Hz | |||||||||
Maximum Motor Voltage | N/A 600 VAC at 50/60 Hz | |||||||||
Load Current Setting Range | N/A 0.5 to 6 A | N/A 1 to 12 A | N/A 3 to 30 A | N/A 5 to 60 A | N/A 10 to 100 A | |||||
Trip Output Relay Status - Energized/Fail Safe to Open | N/A Manual Setting | |||||||||
Trip Output Relay Status - Energized/Fail Safe Close | N/A Automatic Setting | |||||||||
Trip Output Relay Contact Rating | N/A 3A Load | |||||||||
Start Time Setting Range | N/A 0.2 to 10 s | |||||||||
Shock Time Setting Range | N/A 0.2 to 5 s | |||||||||
Input Voltage for Operation | N/A | |||||||||
Allow. Input Voltage Fluctuation | N/A 10 % | |||||||||
Meter Fine Tuning Adjustment | N/A | |||||||||
Output Contact1 | N/A 3A/250 VAC, Resistive | |||||||||
Test Button | N/A Yes | |||||||||
Test Function | N/A Built In | |||||||||
Withstanding Voltage | N/A 2000 VAC, 5 mA at 60 Hz for 1 min. between terminal and enclosure | |||||||||
Surface Color | N/A | |||||||||
Weight_SYN | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 0.440 lb0.20 kg | N/A 1.540 lb0.70 kg | |||||
Shock Relay Power Supply | N/A 90 to 240 VAC | |||||||||
Power Consumption | N/A 2 W | |||||||||
Operating Temperature Range | N/A -4 to 140 ºF-20 to 60 ºC | |||||||||
Max. Elevation | N/A 2000 m6500 ft | |||||||||
Operating Humidity | N/A 45 to 85% R.H. with no condensation | |||||||||
Atmosphere | N/A Free of corrosive gas and dust. Pollution degree 3 or below when installed in control box | |||||||||
Protection Rating | N/A IP20 | |||||||||
Construction Material | N/A Material Lower Housing - PA66 Material Upper Housing - PA6 Terminal Cover - PA6 | |||||||||
Industry Standards/Certifications_SYN | N/A CCC - China CE Marking - Europe RoHS Compliant UL/cUL - North America | |||||||||
Mounting Type_SYN | N/A 35 mm DIN Rail or Mounting Plate | |||||||||
Ambient Temperature Range_SYN | N/A -22 to 158 ºF-30 to 70 ºC | |||||||||
|